Sign In | Join Free | My xpshou.com
China Suzhou Delfino Environmental Technology Co., Ltd. logo
Suzhou Delfino Environmental Technology Co., Ltd.
Create value for customers!
Verified Supplier

5 Years

Home > Water Quality Analyzer >

0 ~ 8bar 50℃ Chlorine Dioxide Analyzer For Drinking Water Disinfection

Suzhou Delfino Environmental Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

0 ~ 8bar 50℃ Chlorine Dioxide Analyzer For Drinking Water Disinfection

Brand Name : Daruifuno

Model Number : ADS2-U3D-CD4.2-AS2/AS3

Certification : CE

Place of Origin : China

MOQ : Negotiable

Price : Negotiable

Product Name : Chlorine Dioxide Controller

Product Model : ADS2-U3D-CD4.2-AS2/AS3

Software Version : DRFN Chlorine Dioxide Analysis software V1.0

Display Range : 0.00-200.00mg/L

Protection Grade : IP66

Size : 144*144*120mm

Power Supply : 18~36V DC

Weight : 800g

Power Consumption : 12W

Mounting Method : Wall mount, pipe clamping, panel

Contact Now

0 ~ 8bar 50℃ Chlorine Dioxide Analyzer For Drinking Water Disinfection



Introduction

The ADS2-U3D-CD4.2-AS2/AS3 chlorine dioxide analyzer is a single-parameter instrument. It is compatible with DRFN's chlorine dioxide sensors. The chlorine dioxide analyzer with AS2 sensor can be used under the temperature of 0-50℃, with AS3 sensor can be used under the temperature of 0-70℃. They both can work under the pressure range of 0 ~ 8 bar.


Advantages Of Chlorine Dioxide Analyzer

1. Menu password can be set to facilitate hierarchical management;

2. A two-wire RS485 interface, the communication protocol is MODBUS RTU. The chlorine dioxide controller supports JSON text data format.

3. All the configuration entered by the user is kept indefinitely, even if there is no power, the data will not be lost.

4. 128*64 black and white graphic dot matrix screen, and the display backlight provides always on and energy-saving mode selection.

5. It has time and historical data recording functions to meet higher data management requirements.

6. Abundant output meets monitoring, control, and remote data transmission at the same time.

Applications Of Chlorine Dioxide Analyzer

The instrument is used for disinfectant measurement in drinking water, swimming pool and industrial cooling water, water plant effluent and municipal pipe network monitoring.

Parameters Of Chlorine Dioxide Analyzer

Product Name Chlorine dioxide analyzer
Product Model

ADS2-U3D-CD4.2-AS2/AS3

Software Version

DRFN chlorine dioxide Analysis software V1.0

Display Range

0.00-200.00mg/L

Resolution

0.001 mg/L

Accuracy

Better than 0.15% of the measuring range

Stability

0.05% of the measuring range every 24 hours, no accumulation

Repeatability

Better than 0.1% of the measuring range

Relay Control

2 settable SPST relays, the max. load 3A/250VAC

Sensor Self-diagnosis

screen image and buzzer prompt

Analog Current Output

2 settable 0/4~20mA active current loop output max. load 1000Ω

Communication Method

MODBUS RTU; support JSON text data format

Display Screen

128*64 LCD

Time History/Data Record

Year/month/day/hour/min/second, record 14000 historical data

Protection Grade

IP66

Operating Environment

0~60℃, relative humidity less than 95%

Storage Environment

-20~70℃, relative humidity less than 55%

Shell Material

Enhanced ABS

Dimensions

144*144*120mm (hole size 138*138 mm)

Mounting Method

Wall mounting, pipe clamping, panel installation

Power Supply

18~36V DC

Weight

800g

Power Consumption

12W


0 ~ 8bar 50℃ Chlorine Dioxide Analyzer For Drinking Water Disinfection
The Matching Chlorine Dioxide Sensor Recommendation

  • Model: AS2/AS3
  • pH range: 1~12
  • Pressure range: 0~8 bar
  • Temperature range: 0~50℃ (AS2), 0~70℃(AS3)
  • Automatic temperature compensation
  • Response time: T90 about 30 s
  • Flow rate: about 30 l/h
  • Shaft length: standard 175 mm, and up to 220 mm in length (mA-Version)
  • Connection: for mA-version 2-pole terminal, M12 male
  • Material: PVC-U (AS2), PEEK (AS3)

Type:

(50℃)

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number
AS2MA1-CD 0.03~1.00 0.01

4~20 mA

12~30 V DC

RL:50~900Ω

3326151
AS2MA2-CD 0.03~2.00 0.01 3326152
AS2MA5-CD 0.03~5.00 0.01 3326153
AS2MA1-CD-M12 0.03~1.00 0.01 3426840
AS2MA2-CD-M12 0.03~2.00 0.01 3426841
AS2MA5-CD-M12 0.03~5.00 0.01 3426842


Type:

(70℃)

Measuring range:

ppm

Resolution:

ppm

Output signal Power supply Item number
AS3MA1-CD 0.03~1.00 0.01 4~20 mA

12~30 VDC

RL :50~900Ω

3326161
AS3MA2-CD 0.03~2.00 0.01 3326162
AS3MA5-CD 0.03~5.00 0.01 3326163
AS3MA1-CD-M12 0.03~1.00 0.01 3426890
AS3MA2-CD-M12 0.03~2.00 0.01 3426891
AS3MA5-CD-M12 0.03~5.00 0.01 3426892



Product Tags:

8bar chlorine dioxide analyzer

      

IP66 chlorine dioxide meter

      

12W chlorine dioxide analyzer

      
China 0 ~ 8bar 50℃ Chlorine Dioxide Analyzer For Drinking Water Disinfection wholesale

0 ~ 8bar 50℃ Chlorine Dioxide Analyzer For Drinking Water Disinfection Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Suzhou Delfino Environmental Technology Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)